{"product_id":"poolex-megaline-fi2-100kw-heat-pump","title":"Heat pump Poolex Megaline Fi2 100kW","description":"\u003ch2\u003ePoolex Megaline Fi2 100 kW – Full Inverter heat pump for large pools\u003c\/h2\u003e\n\u003cp\u003eThe Poolex Megaline Fi2 is a powerful and energy-efficient pool heat pump for larger installations where stable performance and operational reliability are crucial. It is built with Full Inverter technology and can operate year-round within a wide temperature range. Its vertical design reduces the ground area required for installation.\u003c\/p\u003e\n\u003cp\u003eThe heat pump is reversible, meaning it can both heat and cool. Automatic defrosting via reverse cycle ensures it maintains good function even at lower outdoor temperatures.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull Inverter technology\u003c\/li\u003e\n\u003cli\u003eRefrigerant R32\u003c\/li\u003e\n\u003cli\u003eThree-phase 380–415 V\u003c\/li\u003e\n\u003cli\u003eReversible operation (heating and cooling)\u003c\/li\u003e\n\u003cli\u003eAutomatic defrosting via reverse cycle\u003c\/li\u003e\n\u003cli\u003eAutomatic thermostat control\u003c\/li\u003e\n\u003cli\u003eVertical design for reduced space requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eHeat pump: 3 years. Compressor: 7 years. Titanium heat exchanger: 15 years against corrosion.\u003c\/p\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMegaline Fi 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380–415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMitsubishi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter rotary hermetic DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWater flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15°C to 43°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level at 10 m (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 mVp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 × 115 × 240 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and operating data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended pool volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequest sizing documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eConditions: Air 26°C \/ Water 26°C \/ 80% RH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax heating power (kW)\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin heating power (kW)\u003c\/td\u003e\n\u003ctd\u003e31.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (kW)\u003c\/td\u003e\n\u003ctd\u003e19.3 to 2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e13.59 to 6.98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eConditions: Air 15°C \/ Water 26°C \/ 70% RH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax heating power (kW)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin heating power (kW)\u003c\/td\u003e\n\u003ctd\u003e23.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (kW)\u003c\/td\u003e\n\u003ctd\u003e20.0 to 3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP\u003c\/td\u003e\n\u003ctd\u003e7.58 to 4.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 V \/ 3 \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8°C to 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15°C to 43°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax power (kW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 \/ 13.46 \/ 20 \/ 29.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow (m³\/h)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 \/ 20.5 \/ 35 \/ 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR32, 6.5 kg x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2148 × 1076 × 2176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax current (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydraulic connections (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level 1 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e? 73 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level 10 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e? 53 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMitsubishi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of compressors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTitan, Twisted Tech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeating \/ Cooling \/ Silent mode \/ Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure drop (mVp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor this power level, a sizing check based on pool volume, desired temperature, covering, and operating season is always recommended.\u003c\/p\u003e","brand":"Poolex","offers":[{"title":"Default Title","offer_id":57262243119429,"sku":"POS-PC-MLP1002N","price":359000.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/4073\/7515\/files\/Megaline-Fi_galerie08.jpg?v=1772187042","url":"https:\/\/villahome.se\/en\/products\/poolex-megaline-fi2-100kw-heat-pump","provider":"Villahome.se","version":"1.0","type":"link"}