- Product type: Wood stove
- Fuel: Wood
- Nominal heat output: 7.6 kW
- Heatable area: up to 100 m² according to the supplier
- Efficiency: 76%
- Fine particulate matter: 18 mg/Nm³
- Energy class: A
- Weight: 172 kg
- Finishes: Steel, soapstone or limestone
- Max log length: 50 cm
- Safety distance rear / side / front: 100 / 450 / 1270 mm
- Fresh air connection: Ø100 mm
- Flue connection: Ø150 mm
- Internal lining: Refractory concrete
- Handle: Full height
- Ash management: Concealed ash pan
- Product dimensions (W × H × D): 764 × 977.5 × 518 mm according to the manufacturer's instructions for O1. Check exact dimensions for stone-clad versions before installation.
Variants and item numbers
| Finish | Item number | SKU | EAN/GTIN |
|---|---|---|---|
| Steel | 30007302 | KAM-30007302 | 3859893103841 |
| Soapstone | 30008311 | KAM-30008311 | 3858893329121 |
| Limestone | 30008221 | KAM-30008221 | 3858893329138 |
The Ember O1 is the lower model in Ember's 50 series. The wide firebox and low silhouette provide a distinctly horizontal view of the fire, while the format differs from the narrower E and F models.
The O1 is available in steel, soapstone, and limestone. The 50 series is designed for longer logs and features a full-height handle and fire-resistant concrete in the combustion chamber. The wide glass front gives the flames plenty of visual space without making the stove tall.
External air intake allows the combustion air to be drawn from outside. The O1 has a significantly larger safety clearance to the side than to the rear, making it important to check the wall and furniture placement before purchase and installation.
Use collapsible tabs for more detailed information that will help customers make a purchasing decision.
Ex: Shipping and return policies, size guides, and other common questions.
Installation
Install the stove according to the Embers installation manual and applicable Swedish regulations. The manufacturer specifies a minimum chimney draft of 12 Pa. The flue, firebox liner, and safety clearances must be sized according to the specific model and its location.
Combustion air and chimney
The stove has a Ø100 mm connection for external combustion air and a Ø150 mm flue connection. In airtight homes, a separate air supply is important to prevent the ventilation from counteracting the chimney draft. Keep air intakes and flue passages clear.
Wood and combustion
The 50 series is designed for wood logs up to 50 cm. Use dry, untreated wood, follow the manual's recommended wood quantity and air control settings, and avoid overfiring. Keep the door closed during normal operation.
First firing
Start with smaller amounts of wood and gradually increase the temperature. Materials and surface treatments may emit odors during the first few firings; ventilate the room until this has subsided.
Care and safety
Allow the stove to cool completely before cleaning. Empty the ash container regularly and inspect the glass, seals, firebox liner, and flue passages. The chimney must be swept at the required intervals. Do not use the stove if the glass is cracked or if there is any other visible damage.