Installation
Install the stove according to the current Plamen manual and applicable Swedish regulations. Kaminexperten specifies at least 400 mm on the sides and 250 mm behind the stove to combustible materials. The base must be level and able to support the product's weight. Floor protection, flue connection, and chimney must be planned before the stove is placed in position.
Combustion air and chimney
The current product data does not specify a separate external air connection. Therefore, ensure sufficient combustion air and pay special attention to kitchen extractor fans or other mechanical exhaust ventilation. The chimney must be clean, airtight, and correctly sized, and must not be subjected to negative pressure that disrupts combustion.
First firing
Heat the stove gradually with smaller amounts of wood during the first few firings. Ventilate the room if the surface treatment or seals emit odors as the product is heated in.
Cooking and oven
The cooking surface and oven are heated by the same fire that heats the room. Build up the temperature gradually and adjust the amount of wood and air regulation according to both cooking and the desired room heat. The oven door, cooking surface, and cookware become very hot during use.
Fuel and firing
Use dry, untreated wood and follow the manual's recommended amount of wood. Keep the firebox door closed during normal operation and avoid overfiring.
Care and safety
Let the stove cool before cleaning. Empty the ash and regularly clean the glass, cooking surface, oven, and flue passages. Keep the flue passages around the oven free from soot and check the seals and flue connection. The chimney must be swept according to the applicable intervals.