- Product type: Fireplace insert
- Series/model: Adour 700
- Fuel: Wood
- Variants at VillaHome: With turbofan / without turbofan
- Nominal output: 7.0 kW
- Output range: 5–9 kW
- Efficiency: 82%
- Energy class: A+
- CO emissions: 0.09%
- Heating volume: 156 m³
- Heating area: 62 m²
- Dimensions (W × H × D): 690 × 490 × 400 mm
- Firebox (W × H × D): 604 × 235 × 290 mm
- Weight: 82 kg
- Max log length: 60 cm
- Flue connection: Ø150 mm
- Exterior material: Steel
- Firebox lining: Vermiculite
- External air supply: Yes
- Features: Double combustion, Easy Fire Control, Extra Clean Glass, Cleaning Access, Silence Mode on the version with a turbine
- CE marking: Yes. Documentation: declaration of performance (DoP)
The Lacunza Adour 700 is a wide, front-glazed wood insert where the black frame gives the fire a distinct place in the wall. Compared to the Adour 500 and 600, the fireplace is more spacious, while the straight front maintains a calmer look than the corner-glazed CLI/CLD models.
Choose between versions with or without a turbofan. The fan version can move the heated air with active ventilation and has Silence Mode when the fan needs to be turned off. The fanless variant lacks the turbofan function. Both are intended for wood burning and have the option for external combustion air.
The Adour 700 is delivered as a built-in insert without a finished mantel. The framing must be designed for convection air, smoke connection, and access for sweeping and service. Choose the Adour 700 if you want a wider front-glazed fireplace, but do not need visibility from the side or the larger format of the Adour 800.
Installation
Installation must be carried out by a qualified installer in accordance with the Lacunza manual and applicable regulations. For the Adour 700, the manual specifies safety distances to combustible materials of 300 mm above, 1500 mm in front, and 250 mm to the sides/behind. The support and surround must be designed to withstand the weight and thermal load of the completed installation.
Recessing and ventilation
When recessing, Lacunza specifies a minimum fresh air opening of 1000 cm² below the appliance and a minimum hot air outlet of 1250 cm² above. These openings must be kept clear. External combustion air is connected in accordance with the manual when used.
Firing, care and servicing
Before the first firing, check the glass, flue, seals, door closure and deflector. Burn dry wood and follow the recommended wood quantity. Clean the glass, ash compartment, air intakes and flue passages when the insert is cold. Ensure access for chimney sweeping/servicing and keep the turbine's airways clean on the fan version.
Combustion air and chimney
Size the chimney according to the model's flue connection and check whether the relevant version has external air supply. Air ducts and any ducted hot air must be planned before the surround is closed and must remain accessible for inspection.
Firing and air control
Use dry, untreated wood and follow the Lacunza manual for wood quantity and air control. Double combustion and glass air flushing work best when the airways are kept clear and the fireplace is not overloaded. Open the door slowly when refilling wood and avoid overfiring.