- Product type: Wood stove
- Fuel: Wood
- Nominal heat output: 7.0 kW
- Heatable area: up to 125 m² according to the manufacturer
- Efficiency: 80%
- Fine particulate matter: 22 mg/Nm³
- Weight: 152 kg
- Finishes: Steel, soapstone or limestone
- Max log length: 33 cm
- Distance to combustible material (side / rear / front): 180 / 420 / 1150 mm
- Fresh air connection: Ø100 mm
- Flue connection: Ø150 mm
- Door: Screen-printed glass door
- Interior lining: Fireclay
- Wood storage: Open compartment below the firebox; doors optional
- Ash management: Concealed ash container
Finishes and item numbers
| Finish | Item number | SKU | EAN/GTIN |
|---|---|---|---|
| Steel | 30009220 | KAM-30009220 | 3858893329060 |
| Soapstone | 30013007 | KAM-30013007 | 3858893329428 |
| Limestone | 30009425 | KAM-30009425 | 3858893329084 |
The Ember D19 VG features a tall, cohesive fireplace body where the open wood compartment beneath the firebox takes a prominent place in the design. Wood can be stored close at hand, and the compartment can be fitted with model-specific doors for a more enclosed look. The doors are optional extras and are not included.
The wide glass door provides a view of the fire, while the vertical handle and concealed ash container keep the front uncluttered. The firebox is lined with fireproof concrete. The D19 VG is available in steel, soapstone, or limestone – three finishes that give the same basic form a different character.
The fireplace is intended for wood burning and can be connected to external combustion air. Before purchasing, it is important to compare the finishes and ensure that the flue connection, floor protection, and distances to combustible surfaces are suitable for the intended location.
Use collapsible tabs for more detailed information that will help customers make a purchasing decision.
Ex: Shipping and return policies, size guides, and other common questions.
Installation
Install the stove according to the Embers installation manual and applicable Swedish regulations. The manufacturer specifies a minimum chimney draft of 12 Pa. The flue, firebox liner, and clearances to combustible materials must be designed according to the specific model.
Combustion air and chimney
The stove has a Ø100 mm connection for external combustion air and a Ø150 mm flue connection. In airtight homes, a planned supply air solution is important to prevent the ventilation from counteracting the chimney draft. Air intakes and flue paths must be kept clear.
First firing
Start with smaller amounts of wood and gradually increase the temperature. Ventilate the room if paint and materials emit odors during the first few firings.
Firing
Use dry, untreated wood and follow the manual's instructions for wood quantity and air control. Keep the door closed during normal operation and avoid overfiring.
Care and safety
Allow the stove to cool completely before cleaning. Empty the ash container regularly and inspect the glass, seals, firebox liner, and flue paths. The chimney must be swept at the required intervals. Do not use the stove if the glass is cracked or if there is any other visible damage.
Manual
Öppna manual (PDF)Use collapsible tabs for more detailed information that will help customers make a purchasing decision.